Review



hpx 87p ion exchange column  (Bio-Rad)


Bioz Verified Symbol Bio-Rad is a verified supplier
Bioz Manufacturer Symbol Bio-Rad manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    Bio-Rad hpx 87p ion exchange column
    Hpx 87p Ion Exchange Column, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 99/100, based on 1032 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hpx+87p+ion+exchange+column/Aminex+HPX-87P+Analytical+Column/pmc03806156-127-2-6
    Average 99 stars, based on 1032 article reviews
    hpx 87p ion exchange column - by Bioz Stars, 2026-10
    99/100 stars

    Images

    Related Articles

    High Performance Liquid Chromatography:

    Article Title: Identification of Important Amino Acids in Gal2p for Improving the L -arabinose Transport and Metabolism in Saccharomyces cerevisiae
    Article Snippet: .. The high-performance liquid chromatography (HPLC) prominence LC-20A (Shimadzu, Japan), which has a refractive index detector RID-10A (Shimadzu, Japan) and an Aminex HPX-87P ion exchange column (Bio-Rad, United States), was used to determine the concentration of the above chemicals at 80°C with a mobile phase of water at a flow rate of 0.6 mL min -1 , as previously reported ( ; ). ..

    Article Title: Coutilization of D-Glucose, D-Xylose, and L-Arabinose in Saccharomyces cerevisiae by Coexpressing the Metabolic Pathways and Evolutionary Engineering
    Article Snippet: .. The high performance liquid chromatography (HPLC) prominence LC-20A (Shimadzu, Japan) with a refractive index detector RID-10A (Shimadzu, Japan) and an Aminex HPX-87P ion exchange column (Bio-Rad, USA) was used to determine the concentration of the above chemicals at 80°C with a mobile phase of water at a flow rate of 0.6 mL min −1 , as reported [ , ]. ..

    Article Title: Organic brown sugar and jaboticaba pulp influence on water kefir fermentation
    Article Snippet: .. Carbohydrates were analyzed by HPLC (Shimadzu Corporation, Kyoto, Japan) composed of high pressure pump (LC-20AT); automatic injection (SIL-20AC HT), at the flow rate of 1.0 mL min-1, with injection volume adjusted to 20 μL; detector by refractive index (RID-10A); column furnace (CTO-20A) maintained at a constant temperature of 85 °C; (CBM20A) and Aminex HPX-87P ion exchange column (7.8 x 300 mm in ionic form Pb-2, Biorad, CA, USA). ..

    Article Title: Nutritional quality and technological potential of pitaya species
    Article Snippet: Then, the suspensions were filtered using a Sep-Pak cartridge (Waters) and 0.22 μm cellulose acetate membrane (Sartorius). .. The sugars were separated and quantified using a high-performance liquid chromatography (HPLC) system (Shimadzu LC 20 A, Kyoto, Japan) using a high-pressure pump (LC-20AT), automatic injector (SIL-20AC HT), 20 μL injection loop, refractive index detector (RID-10A), with a flow rate of 1.0 mL min-1, column oven (CTO-20A) at 85 °C, control module (CRM-20A), and Aminex HPX-87P ion exchange column (7.8 × 300 mm ion exchange Pb+2, Biorad, CA, USA). .. Data acquisition and integration of chromatographic peaks were performed using LC Solutions software (Shimadzu Co., Kyoto, Japan).

    Refractive Index:

    Article Title: Identification of Important Amino Acids in Gal2p for Improving the L -arabinose Transport and Metabolism in Saccharomyces cerevisiae
    Article Snippet: .. The high-performance liquid chromatography (HPLC) prominence LC-20A (Shimadzu, Japan), which has a refractive index detector RID-10A (Shimadzu, Japan) and an Aminex HPX-87P ion exchange column (Bio-Rad, United States), was used to determine the concentration of the above chemicals at 80°C with a mobile phase of water at a flow rate of 0.6 mL min -1 , as previously reported ( ; ). ..

    Article Title: Coutilization of D-Glucose, D-Xylose, and L-Arabinose in Saccharomyces cerevisiae by Coexpressing the Metabolic Pathways and Evolutionary Engineering
    Article Snippet: .. The high performance liquid chromatography (HPLC) prominence LC-20A (Shimadzu, Japan) with a refractive index detector RID-10A (Shimadzu, Japan) and an Aminex HPX-87P ion exchange column (Bio-Rad, USA) was used to determine the concentration of the above chemicals at 80°C with a mobile phase of water at a flow rate of 0.6 mL min −1 , as reported [ , ]. ..

    Article Title: Organic brown sugar and jaboticaba pulp influence on water kefir fermentation
    Article Snippet: .. Carbohydrates were analyzed by HPLC (Shimadzu Corporation, Kyoto, Japan) composed of high pressure pump (LC-20AT); automatic injection (SIL-20AC HT), at the flow rate of 1.0 mL min-1, with injection volume adjusted to 20 μL; detector by refractive index (RID-10A); column furnace (CTO-20A) maintained at a constant temperature of 85 °C; (CBM20A) and Aminex HPX-87P ion exchange column (7.8 x 300 mm in ionic form Pb-2, Biorad, CA, USA). ..

    Article Title: Nutritional quality and technological potential of pitaya species
    Article Snippet: Then, the suspensions were filtered using a Sep-Pak cartridge (Waters) and 0.22 μm cellulose acetate membrane (Sartorius). .. The sugars were separated and quantified using a high-performance liquid chromatography (HPLC) system (Shimadzu LC 20 A, Kyoto, Japan) using a high-pressure pump (LC-20AT), automatic injector (SIL-20AC HT), 20 μL injection loop, refractive index detector (RID-10A), with a flow rate of 1.0 mL min-1, column oven (CTO-20A) at 85 °C, control module (CRM-20A), and Aminex HPX-87P ion exchange column (7.8 × 300 mm ion exchange Pb+2, Biorad, CA, USA). .. Data acquisition and integration of chromatographic peaks were performed using LC Solutions software (Shimadzu Co., Kyoto, Japan).

    Concentration Assay:

    Article Title: Identification of Important Amino Acids in Gal2p for Improving the L -arabinose Transport and Metabolism in Saccharomyces cerevisiae
    Article Snippet: .. The high-performance liquid chromatography (HPLC) prominence LC-20A (Shimadzu, Japan), which has a refractive index detector RID-10A (Shimadzu, Japan) and an Aminex HPX-87P ion exchange column (Bio-Rad, United States), was used to determine the concentration of the above chemicals at 80°C with a mobile phase of water at a flow rate of 0.6 mL min -1 , as previously reported ( ; ). ..

    Article Title: Coutilization of D-Glucose, D-Xylose, and L-Arabinose in Saccharomyces cerevisiae by Coexpressing the Metabolic Pathways and Evolutionary Engineering
    Article Snippet: .. The high performance liquid chromatography (HPLC) prominence LC-20A (Shimadzu, Japan) with a refractive index detector RID-10A (Shimadzu, Japan) and an Aminex HPX-87P ion exchange column (Bio-Rad, USA) was used to determine the concentration of the above chemicals at 80°C with a mobile phase of water at a flow rate of 0.6 mL min −1 , as reported [ , ]. ..

    Injection:

    Article Title: Organic brown sugar and jaboticaba pulp influence on water kefir fermentation
    Article Snippet: .. Carbohydrates were analyzed by HPLC (Shimadzu Corporation, Kyoto, Japan) composed of high pressure pump (LC-20AT); automatic injection (SIL-20AC HT), at the flow rate of 1.0 mL min-1, with injection volume adjusted to 20 μL; detector by refractive index (RID-10A); column furnace (CTO-20A) maintained at a constant temperature of 85 °C; (CBM20A) and Aminex HPX-87P ion exchange column (7.8 x 300 mm in ionic form Pb-2, Biorad, CA, USA). ..

    Article Title: Nutritional quality and technological potential of pitaya species
    Article Snippet: Then, the suspensions were filtered using a Sep-Pak cartridge (Waters) and 0.22 μm cellulose acetate membrane (Sartorius). .. The sugars were separated and quantified using a high-performance liquid chromatography (HPLC) system (Shimadzu LC 20 A, Kyoto, Japan) using a high-pressure pump (LC-20AT), automatic injector (SIL-20AC HT), 20 μL injection loop, refractive index detector (RID-10A), with a flow rate of 1.0 mL min-1, column oven (CTO-20A) at 85 °C, control module (CRM-20A), and Aminex HPX-87P ion exchange column (7.8 × 300 mm ion exchange Pb+2, Biorad, CA, USA). .. Data acquisition and integration of chromatographic peaks were performed using LC Solutions software (Shimadzu Co., Kyoto, Japan).

    Control:

    Article Title: Nutritional quality and technological potential of pitaya species
    Article Snippet: Then, the suspensions were filtered using a Sep-Pak cartridge (Waters) and 0.22 μm cellulose acetate membrane (Sartorius). .. The sugars were separated and quantified using a high-performance liquid chromatography (HPLC) system (Shimadzu LC 20 A, Kyoto, Japan) using a high-pressure pump (LC-20AT), automatic injector (SIL-20AC HT), 20 μL injection loop, refractive index detector (RID-10A), with a flow rate of 1.0 mL min-1, column oven (CTO-20A) at 85 °C, control module (CRM-20A), and Aminex HPX-87P ion exchange column (7.8 × 300 mm ion exchange Pb+2, Biorad, CA, USA). .. Data acquisition and integration of chromatographic peaks were performed using LC Solutions software (Shimadzu Co., Kyoto, Japan).



    Similar Products

    86
    Aminex Therapeutics ion exchange aminex hpx 87p column
    Ion Exchange Aminex Hpx 87p Column, supplied by Aminex Therapeutics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hpx+87p+ion+exchange+column/87h+aminex+column+hpx/10__1016_slash_j__fuel__2024__130887-102-13-14
    Average 86 stars, based on 1 article reviews
    ion exchange aminex hpx 87p column - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    99
    Bio-Rad hpx 87p ion exchange column
    Hpx 87p Ion Exchange Column, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hpx+87p+ion+exchange+column/Aminex+HPX-87P+Analytical+Column/pmc03806156-127-2-6
    Average 99 stars, based on 1 article reviews
    hpx 87p ion exchange column - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    90
    Bio-Rad ion exchange column (hpx-87p
    Ion Exchange Column (Hpx 87p, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hpx+87p+ion+exchange+column/aminex+hpx+87h+column/us11230627-77-14-21
    Average 90 stars, based on 1 article reviews
    ion exchange column (hpx-87p - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results